"Inspection Due" or "Inspection Required" message on the DM100i-DM200i and DM110i-DM220i

UPDATED: 10 January 2019


UK postal regulations require that a meter be inspected periodically. This inspection occurs automatically when your meter is refilled with postage, when your system connects to the Pitney Bowes Data Centre to perform a balance enquiry, or to perform a data upload.

If a connection to the Pitney Bowes Data Centre does not occur within a 90 day period, the meter will display Inspection Due or Inspection Required.
  • Inspection Due can be cleared by connecting to the Pitney Bowes Data Centre, or pressing the clear button.
  • Inspection Required can only be cleared by connecting to the Pitney Bowes Data Centre. Until a successful connection is made, the meter is locked and cannot print postage.
To clear an inspection message:
  1. Before you start, ensure that your system is connected via SmartLink™ (UK DM100), wired or wireless LAN, PC Meter Connect, or via analogue phone line, in order to communicate with the Pitney Bowes Data Centre.
  1. If your meter's screen is not displaying Connect now, skip to step 7.
  2. Select Connect now.
  3. Select Continue.
  4. Select Check PBP Balance. The meter connects to the Pitney Bowes Data Centre and displays your available balance.
Note: If the meter is unable to connect to the Pitney Bowes Data Centre, see the DM100-DM220 Connecting Your Product or DM110i-DM220i Connecting Your Product section.
  1. Press No to return to the Main screen. The inspection message should have cleared. If the inspection message continues to display, follow these steps:
  2. Press Add Postage.
  3. Select "Check PBP Balance". The meter connects to the Pitney Bowes Data Centre and displays your available balance.
Note: If the meter is unable to connect to the Pitney Bowes Data Centre, see the Connecting Your Product section for assistance troubleshooting connection issues.
  1. Press No to continue without adding postage. The meter will check for any available updates.
  2. If updates are available, select Get update now. Updates will download and install automatically.
  3. After the updates have been installed, select Continue. The inspection message should now be cleared.

If the inspection message is not cleared after following these steps and making a successful connection, contact Technical Support. Please have your Meter type (PCN) and Serial Number (Meter #) ready, these can be located on a white sticker at the back of the meter.

Environment Details

Products affected:
DM100i / DM150i / DM200i (P720)
DM110i / DM160i / DM220i (PR20)