Generating a CASS 3553 report with the CODE-1 Plus provided installation verification job (sample, IVPFILE, @IVP@)

Products Affected:  CODE-1 Plus
In order to generate a CASS 3553 form by running the CODE-1 Plus sample installation verification, certain parameters needed to be ""uncommented" and one parameter needs to be added.  For z/OS, the sample installation verification job name is IVPFILE, for IBMi, the job name is @IVP@, and for Unix and Windows, the job is called "sample".

Here are the parameters distributed with the sample installation verification job (for the purpose of this article, these parameters are from the IVPFILE JCL member on the z/OS platform; the parameters may differ slightly for other platforms such as the FILEDF format):

FILEDF C1BMNAM  F 0256 32512
FILEDF C1BMCOK  F 0256 32512
FILEDF C1BMNCO  F 0256 32512
HEADER            CODE-1 PLUS
CONTRL
LOTOUT 180 182 187 190 193 B
*AUXIL1
* Include the following parameter if running DPV Split
*DPVIN  Y Y Y Y Y Y Y
* Include the following parameter if running DPV Flat
*DPVIN  Y Y Y Y Y Y Y                                 F
* Include the following parameter if running DPV Full
*DPVIN  Y Y Y Y Y Y Y                                 H
*DPVOUT 200 201 202     203 204
*MAILER Pitney Bowes Software
*MAILER 4200 Parliament Place
*MAILER Lanham
*MAILER MD
*MAILER 20706-1852
* Include the following parameter if running LACS
*LACS   Z
*AM2OUT                                             245 250
* Include the following two parameters if running SuiteLink
*STELNK W   299                                                                N
*FIRMNM U      102 40                                                   I
ADDRDF L 071 35 106 35
CS ZIP S 163 C 141 20 161 02     168 C
Z5 OUT     163 C
Z4 OUT     168 C
CR OUT     172
CS OUT     141 20       161
SA OUT     071 70                                                      X
AP OUT                       X 071 35 X 106 35
CONFIG M M M N

In order to make this job produce a CASS 3553 form, you would need to "uncomment" the following parameters:

* Include the following parameter if running DPV Split
*DPVIN  Y Y Y Y Y Y Y
* Include the following parameter if running DPV Flat
*DPVIN  Y Y Y Y Y Y Y                                 F
* Include the following parameter if running DPV Full
*DPVIN  Y Y Y Y Y Y Y                                 H

*DPVOUT 200 201 202     203 204
*MAILER Pitney Bowes Software
*MAILER 4200 Parliament Place
*MAILER Lanham
*MAILER MD
*MAILER 20706-1852
*LACS   Z
*AM2OUT                                             245 250
*STELNK W   299                                                                N
*FIRMNM U      102 40                                                   I

NOTE:  For STELNK, change the W in column 8 to an S

You will also have to add an SA2OUT parameter and pass a Y in position 15.

These changes should allow the our sample installation verification job to generate a CASS 3553 Report.

 
UPDATED:  June 14, 2019