VERIFIED SOLUTION i

How to get parsed address data using the CODE-1 Plus batch driver, C1BM00

Products Affected:  CODE-1 Plus
In order to get parsed address elements returned when executing C1BM00, add the AE OUT parameter and specify output locations for each element:

1-6 KEYWORD AE OUT 
8-10 Location for HOUSE NUMBER
12-14 Location for LEADING DIRECTIONAL
16-18 Location for STREET NAME
20-21 Length of STREET NAME
23-25 Location for SUFFIX
27-29 Location for TRAILING DIRECTIONAL
31-33 Location for APARTMENT DESIGNATOR
35-37 Location for APARTMENT NUMBER
39-41 Location for RURAL ROUTE/HIGHWAY CONTRACT ROUTE TYPE
43-45 Location for RURAL ROUTE/HIGHWAY CONTRACT NUMBER
47-49 Location for BOX NUMBER

In addition, we recommend that you pass an N or an M for the Disposition Indicator:

51 DISPOSITION INDICATOR Code indicating what should be stored in cases where standardized elements could not be stored (because no match was found).

Enter one of the following codes:
• B — Store blanks.
• M — Store elements from normalized address merging secondary address line elements with primary address line elements. In cases where an element appears in both the primary and secondary address lines, use the element from the primary address line.
• N — Store elements from normalized address using the primary address line only.
• X — Store nothing.
UPDATED:  September 4, 2017