Canadian Code-1 Plus Version 3.3.7 Error with C6RUNJOB

UPDATED: April 4, 2017


Canadian Code-1 Plus Version 3.3.7
When submitting Interactive Command "C6RUNJOB" results in the below abend...

Device *REQUESTER not found while opening file C6CPID00 in library 
G1C6PGMS. 
Error message CPF4103 appeared during OPEN. 
Function check. RNX1217 unmonitored by C6CALCRLN at statement 0000003384, 
instruction X'0000'. 
Error message CPF4103 appeared during OPEN (C G D F). 

Message ID . . . . . . : CPF4103 Severity . . . . . . . : 40 
Message type . . . . . : Escape 
Date sent . . . . . . : 03/08/16 Time sent . . . . . . : 07:56:07 

Message . . . . : Device *REQUESTER not found while opening file C6CPID00 in 
library G1C6PGMS. 
Cause . . . . . : The device name specified for this file cannot be found. 
Recovery . . . : Do one of the following, and then try the request again: 
-- Correct DEV parameter on the appropriate Create, Change, or Override 
File command. 
-- Create the appropriate device description. 

The submitting command from our CL is: 

C6RUNJOB JOBID(STD03) INPFIL(G1WORK/LCSX73AP) + 
INPMBR(CANADA) OUTLEN(590) + 
CODEDFIL(G1WORK/C1SX73AP) + 
CODEDMBR(CANADA) INVPCD(Y) UNCODED(Y) + 
DBLIB(G1C6FILES) 

Temporarily Work-around
C6RUNJOB and C6SBMJOB commands run successfully from the command line.

Permanent fix:  One-Off S01 Patch 
 

Environment Details

Product Feature: General

Operating System: iSeries
 