Mailstream Plus - MSP Error Message - Can only have 1 ENT PT when SCF PT used

Product Feature: Parameters

Operating System: all platforms

 

Issue

MailStream Plus produces the error message [Can only have 1 ENT PT when SCF PT used] when you have the parameters NDC PT, SCF PT, and two ENT PT cards.
ENT PT     Origin    60699 CHICAGO IL 60699                  N O       Y
ENT PT     Offshore  60699 CHICAGO IL 60699                  N O
######                                                                           0011: Can only have 1 ENT PT when SCF PT used
TB LKP 1 344 3 383 9 006       009        Offshore
TB LKP 1             967       969        Offshore
TB LKP 1             995       999        Offshore
TB LKP 1 NOHIT 383 9                      Origin
NDC PT YNY                                                  X
SCF PT YN                                                  Y

Cause

MailStream Plus produces the error message [Can only have 1 ENT PT when SCF PT used] when you have the parameters NDC PT, SCF PT, and two ENT PT cards.

Resolution

UPDATED: October 16, 2017
Information From the Reference Guide - All Platforms MailStream Plus Release 8.3.3 page 287
You can have more than one type of XXX PT parameter in a single MailStream Plus job. However, if you use any combination of ADC PT, NDC PT and/or SCF PT parameters, you can only have one ENT PT parameter (and it must be marked as the default in position 72).

The resolution is to add separate ENT PT cards for the NDC entry points and the SCF entry points then add the two 
ENT PT parameter cards.
ENT PT Origin 60699 CHICAGO IL 60699 N O Y