Resolve Drill Through Link Wizard is not available when UAC is enabled in Sagent Data Flow

Issue

Drill through wizard not available in Design Studio when UAC is enabled under Windows 7 machine.

Scenario: When UAC is enabled
  • In Design Studio, create a sample plan with reports.
  • Execute the plan.
  • Right click on result. Click on Drill Through. 
  • Wizard will not open

Cause

UAC is enabled and Design Studio is not running with admin privileges. 

Resolution

UPDATED: September 7, 2017


Workaround: 
Use any one of the following workaround.
  1. Give the full control to access the below registry, it works fine even if UAC is enabled. 
    HKEY_LOCAL_MACHINE\SOFTWARE\Sagent
  2. Run Design Studio as "Run as administrator".

Environment Details

Product Feature: Design Studio
Operating System: Windows 7, windows 8, 8.1 and Windows Server 2012, Windows Server 2012 R2.


 