Issue

Different output from the same plan (using Sorted Union transform) on different version of Sagent.

Cause

This could happen due to a scenario where column(s) get deleted, during upgrade, from the key column list of Sorted Union transform after upgrading from Sagent.

Resolution

UPDATED: December 26, 2017


Try following steps to get the desired results:
  • Open the plan in Design Studio.
  • Open the properties of 'Sorted Union Transform'.
  • Switch to Advance tab.
  • Uncheck the option that 'Data is presorted'.
  • Press OK.
If the issue is still not resolved, contact client support.