VERIFIED SOLUTION i

Resolve an E-Z Seal leak on the DM100i, DM125, DM200L, DM225 and more

Products affected: DM100®i, DM125™, DM200L™, DM225™, DM300C™, SendPro® 300

Issue

The moistener is leaking E-Z Seal®.

Cause

The moistener may be overfilled or cracked.

Resolution

UPDATED: May 7, 2018
The moistener should only be filled until the window is approximately ¾ full.

If the moistener is overfilled:
  1. Press the blue switch to detach it from the meter.
  2. Place it upside down in a sink to drain some of the fluid out of until it is approximately ¾ full.
  3. Reinstall it into the meter.
If the moistener is not overfilled, then it is likely cracked. Contact technical support for a replacement. Please have your model and serial number ready.