VERIFIED SOLUTION i

Resolve "Start Manufacturing Mode" on startup on the Connect+ Series and SendPro P-Series

Products affected: Connect+® 500W, Connect+® 1000, Connect+® 2000, Connect+® 3000, SendPro® P1000, SendPro® P1500, SendPro® P2000, SendPro® P3000

Issue

The meter displays "Start Manufacturing Mode" on startup and loads to a desktop.
 

Cause

The network test was not completed successfully.

Resolution

UPDATED: November 27, 2017
  1. Tap Start Manufacturing Mode.
  2. Tap Settings Icons.
  3. Enter the password. Depending on the software version, the meter may use one of two different passwords:
  • 55555
  • 55694655
  1. Tap Network Test.
  2. Once the test is completed successfully, double-tap MS1 App.
If the network test fails, see Resolve connection issues on the Connect+ series and SendPro P series.