How should Automation v6.5 be installed so that it can coincide with Sagent v6.8 64bit

UPDATED: August 28, 2017


Follow the steps to setup Sagent Automation v6.5 with Sagent v6.8 64bit:
  1. Install Sagent v6.5 client only, (include Design Studio) and Automation. Do not install the Dataflow Server.
  2. It is not required to give any userid/password & Licence at the time of installation of Sagent Automation just press Next button.
  3. Install Sagent v6.8 64bit Dataflow server including the Webservice, and also the 32bit client components like Design Studio and Admin.
  4. Install the v6.8.2 patch.
  5. Then install the Automation Updater. 
  6. Add the following registry setting:
Location:
"HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Sagent\DataMart\WS"

Name: "AgentMachine" Type: REG_SZ Value: <Machine-Name>
Name: "Port" Type: REG_DWORD Value: 18083


Note:
====
  • Sagent Automation is a 32bit application.
  • Sagent Automation is not supported on Windows 2008.
  • Sagent Automation is supported on Windows 2003 64bit and 32bit.

Environment Details

Product Feature: Installation / Upgrade

Operating System: Windows 2003


 