Stalls due to incorrectly adjusted side guides on the Relay 3000 and 4000

Correct stalls due to incorrectly adjusted side guides on the Relay 3000 and 4000.
Products affected: Relay™ 3000, Relay™ 4000

Issue

The machine is experiencing feeding issues or jams.

Cause

The side guides are incorrectly adjusted.

Resolution



To clear the jam:
  1. Remove the insert feeder tray.
  2. Remove the fold plate.
  3. Open envelope inverter access door.
  4. Lift the tinted plastic cover to access the insertion and sealing areas.
  5. Lift the Q-station.
  6. Remove and inspect the stalled material.
To adjust the side guides:
  1. Turn the blue knob and adjust the insert feeder side guides to within 1/8th inch of the sides of the material.
  2. Turn the blue knob and adjust the sheet feeder side guides to within 1/8th inch of the sides of the sheets.
  3. Turn the blue knob and adjust the envelope feeder side guides To within 1/8th inch of the the envelopes.
If the issue is still not resolved, contact client support.

UPDATED: April 04, 2022